What is surge test?

International standard IEC/EN 61000-4-5 defines two different waveform generators: one is the combination wave generator (voltage waveform: 1.2/50μs, current waveform: 8/20μs), and the other is the combination wave generator meeting the requirements of the international Telecommunication Union Commission (voltage waveform: 10/700μs, current waveform: 5/320μs).


The test levels are 1, 2, 3, 4 and X

surge test levels

surge test levelssurge test levelssurge test levels

According to the requirements of IEC/EN 61000-4-5 standard, the lightning surge test on power line and communication line shall be simulated respectively. Due to different impedances of the line, the waveforms of surge on these lines are also different, which should be simulated separately.


(1) Combination wave generator of 1.2/50μs (voltage wave) and 8/20μs (current wave) mainly used for power line test.

Basic circuit diagram as below:

1.2 50 8 20 circuit diagram



(2) Combination wave generator 10/700μs (voltage wave) and 5/320μs (current wave) mainly used for communication line test.

Basic circuit diagram as below:1.2 50 8 20 circuit diagram

10 700 5 320 circuit diagram