The electromagnetic immunity tester consists of three parts: one is interference signal generator and power amplifier equipment, the other is antenna, sensor and other interference signal radiation and injection equipment, and the third is field strength and power detection equipment. The following mainly introduces the equipment of the simulator signal source.
1. Signal source. The signal source has two purposes in the electromagnetic compatibility test: one is a signal generator for system calibration; the other is to promote the power amplifier to generate a continuous wave analog interference signal in the sensitivity test.
2. Peak voltage simulator. The spike voltage simulator is a necessary signal generator for transient spike conduction sensitivity test on equipment or sub-system power lines. Its measurement object is all ungrounded AC or DC power lines that supply power to the DUT from the outside. Transient spike interference caused by switch closure or malfunction when the DUT is working.
3. Lightning surge generator. Switching operations in the power grid and transient overvoltage caused by direct or indirect lightning strikes will cause unipolar transient interference to the equipment. The lightning surge tester is used to test the equipment's ability to withstand unipolar surges.
The occurrence of switching transients is related to the following factors: main power system switching, slight switching actions or load changes near the equipment in the power distribution system, resonant circuits related to switching devices, and various system faults, such as short circuits and arcs in the equipment grounding system Fault. The surge voltage generated by lightning comes from several aspects: one is a direct lightning strike on an external circuit, and the injected large current flows through the ground resistance or external circuit impedance to generate a voltage; the other is the induced voltage on the inner and outer conductors of the building And the indirect lightning strike of the current; the third is the common ground loop of the nearby grounding current of the lightning that is directly discharged to the ground coupled to the equipment grounding system. When the protection device is activated, the voltage and current may change rapidly and may be coupled to the internal circuit.
The surge generator that simulates unipolar transient pulses mainly consists of two parts: a combined wave lightning surge simulator and a coupling/decoupling network.
4. Electrical fast transient pulse group simulator
It is used to generate a series of pulses, test the anti-pulse interference ability of the equipment under test, and evaluate the performance of power supply ports, signal ports and control ports of electrical and electronic equipment when subjected to repetitive fast transient pulse interference. The pulse group interference that appears on the power line, signal line and control line often has the characteristics of short rise time, high repetition frequency, and low energy, which will cause disturbance to electronic equipment.
5. Electrostatic discharge simulator
The electrostatic discharge simulator can simulate the static electricity generated naturally, and is used to assess the performance of electronic and electrical equipment when subjected to electrostatic discharge. The simulation test is carried out in the input and output connectors of the equipment, the case (ungrounded), the keyboard, the switch, the button, the indicator light and other areas that are easily accessible to the operator.