sosinemctest@emcsosin.com    +86-21-67727150
Cont

Have any Questions?

+86-21-67727150

Sep 17, 2022

EFT (Electrical Fast Transient)/Burst Immunity Test (IEC/EN 61000-4-4)

1.     The cause of EFT/burst immunity test (IEC/EN 61000-4-4)

Switching transients (to cut off inductive load, relay contact bounce, etc.) usually interferes with other electrical and electronic equipment in the same circuit. This type of interferences are high amplitude, short rise-time, high repetition rate and low energy.

 

2.     The purpose of EFT/burst immunity test (IEC/EN 61000-4-4)

To establish a common assessment basis for evaluating the performance of electrical and electronic equipment power supply port, signal, control, and grounding ports when subjected to electrical fast transient burst interference.

 

3.     Test levels for electrical fast transient test

            eft test level

 

4.     Features of EFT/burst generator

  • Compliant with latest standard of IEC/EN 61000-4-4 and GB/T17626.4

  • User friendly 7” touch panel display

  • Support multi-language & facilitate users

  • Built-in environment self-test program

  • Programmable operation

  • Pre-programmed IEC/EN 61000-4-4 standard test levels

  • Wave shape of the pulse meet the requirements of 50ohm and 1000ohm load

  • The highest pulse frequency is up to 1.2MHz

  • RS232/USB Port, PC control operation & printable test report

 

5.     IEC/EN 61000-4-4 EFT generator picture

  EFT S4

 

6.     Technical data of IEC/EN 61000-4-4 EFT/burst generator  

Model

EFT S4

Compliant standard

IEC/EN61000-4-4, GB/T 17626.4

Operation

7” touch panel display

Output voltage

0.2 ~5kV

Frequency

1kHz~1200kHz ±10%, continuously adjustable

Polarity

Positive/negative/alternating

Running time

1~9999s, continuously adjustable

Internal impedance

50Ω ±10%

Pulse rise time

5ns ±30%

Pulse width

50ns ±30% (50Ω load)

35ns~150ns (1kΩ load)

Output mode

IEC, user-defined, programmable

Coupling-out

BNC, coupling/decoupling network

Number of pulses

1~255, continuously adjustable

Phase

0~359°synchronous, asynchronous, automatic

Burst period

150~9999ms, continuously adjustable

Coupling/decoupling network

Built-in, single-phase three-line, 16A

(Custom specific on demand)

Power supply

AC 220V ±10% 50/60Hz

Ambient temperature

15℃~35℃

Coupling decoupling network technical parameters

Voltage

0~6kV

Attenuation ratio

<10%

Coupling capacitor

33nF

Coupling mode

L, N, PE freely combined

Capacity

AC 220V 16A

 

7.     Circuit diagram of the EFT generator

           EFT circuit

8.     EFT test configuration: capacitive coupling clamp (optional)

The capacitive coupling clamp can couple EFT (fast transient)/burst to the test line without any electrical connection to the terminal of the device under test, the cable shield, or any other part of the device under test. It is used together with EFT/burst generator and used to do EFT/burst interference test of the I/O data signal line port. Its main purpose is coupling the EFT/burst interference to the I/O data signal line of the EUT. Product fully comply with standard IEC/EN 61000-4-4, GB/T 17626.4.

EFT 4C

Specification:

Max coupling voltage

±7KV

Port

BNC

Coupling capacity

100~1000pF

Specs of coupling plate

140*1000mm

 

9.     Test setup

setup1

                                                         A test setup for laboratory type tests


setup 2

                                               A test setup using a floor standing system of two EUTs

 