Load Dump Generator - Automotive Pulse 5a/5b

Load Dump Generator - Automotive Pulse 5a/5b
Details:
Automotive power failure simulator RV P5, RV P5b also called Load Dump Generator . It is a test device specifically designed to simulate load dump phenomena in automotive power systems. P5 is the transient phenomenon of the load dump. When the battery is disconnected, the AC generator is generating the charging current while the generator circuit is still under other loads. Automotive load dump simulator RV P5, RV P5b can fully meet the latest requirements of ISO 16750-2.
Send Inquiry
Description
Send Inquiry

Overview

 

  • Load dump is a common transient voltage phenomenon in automotive electrical systems, typically occurring when the alternator is supplying power, the battery is suddenly disconnected, or the load is suddenly removed, causing a momentary voltage spike.
  • The load dump generator RV P5, RV P5b generate the pulses A and B according to ISO16750-2, ISO 7637-2 and many other automotive standards. These waveforms are used to test the tolerance and reliability of automotive electronic equipment (such as ECUs, sensors, and in-vehicle entertainment systems) under load dump conditions.
  • Test A - without centralized load dump suppression
  • Test B - with centralized load dump suppression

 

Compliant Standards

 

ISO 16750-2

 

ISO 7637-2

 

GB/T 21437.2

 

GB/T28046.2

Features

 

  • In compliance with ISO 16750-2, ISO 7637-2 and many other standards
  • User friendly 7" color touch panel display
  • One-key switching between Chinese and English language, convenient for different users
  • Capable of generating transients with centralized load dump suppression
  • Built-in adjustable impedance source
  • With various functions, such as control, protection, warning, which can effectively protect the safety of user and system
  • Internal environment self-detection program, which can automatically detect the testing environment and remind user
  • Self-calibrate function to ensure equipment normal operation
  • RS232/Ethernet RJ 45 interface for PC control operation & printable test report

 

Specifications

 

Model

RV P5

RV P5a

12V

24V

Supply voltage (US)

40~102V

100~202V

Input impedance (Ri)

0.5Ω~8Ω

Pulse duration (td)

40ms~400ms

Pulse rise time (tr)

5ms~10ms

Pulse repetition time (t1)

30~9999s

Number of pulses

1~9999

RV P5b

12V

24V

Supply voltage (US)

40~102V

100~202V

Supply voltage with load dump suppression (US1)

20~102V

20~202V

Input impedance (Ri)

0.5~8Ω

Pulse duration (td)

40ms~400ms

Pulse rise time (tr)

5ms~10ms

Pulse repetition time (T1)

30~9999s

Number of pulses (N)

1~9999

EUT capacity

20A

Power supply

AC220V ±10% 50/60Hz

 

Output Waveform

 

Pulse 5a

product-460-346
product-460-346

Pulse 5b

 

Load Dump Generator
product-460-346

Hot Tags: load dump generator - automotive pulse 5a/5b, China load dump generator - automotive pulse 5a/5b suppliers, manufacturers, factory, Automotive ESD simulator, ISO 10605 ESD gun, Automotive Transient Simulator RV P2bP4, ISO 10605 30kV ESD simulator, ISO 7637 Automotive EMC Immunity Testing, automotive transient generator